PE Pressure & Water Supply Pipes — Outside diameter 200 mm

Solid-wall polyethylene pressure and water transmission pipes manufactured in accordance with ISO 4427 and EN 12201-2 in PE100 (P001) and PE80 (P002) grades. Size spectrum spanning outside diameters OD 16 to 630 mm across pressure classes PN4 to PN25 in coils and 6 m / 12 m bars.
2 products found
Comprehensive Buying & Technical Guide

Reference Standards & Technical PE100 vs PE80 Mechanics

Pipes in this category are manufactured to ISO 4427 and EN 12201-2 for potable drinking water, pressurized agricultural irrigation, and industrial fluid transmission. The published product range comprises PE100 Water Pressure Pipe (P001) and PE80 Water Pressure Pipe (P002).

The fundamental mechanical distinction is the design stress: 8.0 MPa for PE100 versus 6.3 MPa for PE80. The nominal pressure rating follows the standard relation PN = 20 × design stress ÷ (SDR - 1). Consequently, to achieve a 16 bar rating (PN16), a PE100 pipe requires SDR 11, whereas a PE80 pipe requires SDR 9, which necessitates a substantially thicker wall.

Dimensional Ranges, SDR Series & Supply Forms

The catalog dimensional envelope covers outside diameters from OD 16 mm up to 630 mm. Pressure classes range from PN4 to PN25, corresponding to standard series SDR 41, SDR 33, SDR 26, SDR 21, SDR 17, SDR 13.6, SDR 11, SDR 9, and SDR 7.4.

Supply packaging depends strictly on outside diameter: diameters up to 110 mm are produced in continuous coils of 100 m and 200 m to eliminate intermediate joints in distribution networks, while sizes from 63 mm upwards are delivered as straight 6 m and 12 m bars.

Jointing Protocols & Trench Bedding for Pressure Lines

Pressure pipe jointing is accomplished through three engineering methods: butt fusion for straight bars and large-diameter mains, electrofusion fittings containing embedded heating coils for critical junctions, and mechanical compression fittings for coiled pipes up to 110 mm.

Pipes must rest on a prepared bed of uniform sand or screened soil free of sharp stones, with a minimum thickness of 10 to 15 cm. Sidefill compaction in staged lifts is essential to restrain lateral deflection. Prior to backfilling and commissioning, hydrostatic field pressure testing must be executed in accordance with the project specifications.

PE Pressure & Water Supply Pipes — Frequently Asked Questions

Which SDR in PE100 corresponds to 10 bar and 16 bar ratings?

In PE100 compound, PN10 corresponds to SDR 17 and PN16 corresponds to SDR 11.

What is the maximum diameter available in coiled water pressure pipes?

Due to coil winding physics and bend radius limits, coiled water pipes are manufactured up to OD 110 mm. Larger diameters are supplied in 6 m or 12 m straight bars.

Do longitudinal blue stripes signify drinking water service?

Yes. Co-extruded blue stripes on the black pipe exterior identify drinking water lines per ISO 4427 and EN 12201-2, distinguishing them from gas and sewage pipelines.

Special Orders & Custom Dimensions

Can't find what you need?

If you require specific sizes, custom fittings or specifications not listed in the catalog, our technical team is ready to assist and review custom requests.