Electrofusion Elbow, Tee & Reducer
Electrofusion 90° elbows, equal tees and reducers for polyethylene gas and water networks; fused with an electrofusion control unit without moving the pipe, 20 to 250 mm.
- Electrofusion 90° elbows, equal tees and reducers
- Heating wire inside the body, fused with an electrofusion unit
- For gas (EN 1555-3) and water (EN 12201-3) networks
- Suits tight spaces where butt fusion is hard
- 20 to 250 mm

Key Specifications
- Product code
- P054
- Reference standard
- EN 12201-3 / EN 1555-3
- Material & grade
- PE
- Outside diameter
- 20–250 mm
- Joint type
- Electrofusion
- Unit of sale
- Piece
- Dimensional options
- 47 rows in the specification table
What electrofusion elbows and tees are for
Electrofusion elbows, tees and reducers, like the electrofusion coupler, have a heating wire inside the body. The pipe ends are cleaned, prepared and pushed into the fitting, and the electrofusion unit passes the right amount of current through the wire so fitting and pipe fuse into one. Because the pipes do not move, the method suits narrow trenches and urban networks.
On gas networks, where weld quality and records matter, electrofusion fittings are the most common choice. These parts are listed to EN 1555-3 for gas and EN 12201-3 for water; state the application in your enquiry.
Electrofusion elbow, tee and reducer sizes
The 90° elbow and equal tee are listed in 20, 25, 32, 40, 50, 63, 75, 90, 110, 125, 140, 160, 180, 200, 225 and 250 mm. The electrofusion reducer joins each diameter to the next smaller one, for example 63 to 50 or 110 to 90 mm.
The electrofusion unit must work up to the largest fitting in the project; the units in our catalogue go up to 160, 250 or 400 mm. In your order give the diameter, the part type, the application (water or gas) and both diameters for a reducer.
Site tips for electrofusion fittings
The quality of an electrofusion joint depends above all on preparing the pipe surface. The outer layer of the pipe in the fusion zone is scraped, the surface is wiped with a clean cloth and a suitable cleaner, and the insertion depth is marked so the pipe goes into the fitting to the right point.
Pipe and fitting must stay still during fusion and cooling, which is why a holding clamp is used. The unit reads the fusion and cooling times from the fitting's barcode; do not load the joint until the cooling time has passed.
Electrofusion Elbow, Tee & Reducer — Technical Specifications
Wall thickness and weight are calculated from the standard series and are approximate; final values are confirmed in the quotation.
| Outer Diameter (mm) | Second Diameter (mm) | Type |
|---|---|---|
| 20 | — | 90° elbow |
| 20 | — | Tee |
| 25 | — | 90° elbow |
| 25 | — | Tee |
| 25 | 20 | Reducer |
| 32 | — | 90° elbow |
| 32 | — | Tee |
| 32 | 25 | Reducer |
| 40 | — | 90° elbow |
| 40 | — | Tee |
| 40 | 32 | Reducer |
| 50 | — | 90° elbow |
| 50 | — | Tee |
| 50 | 40 | Reducer |
| 63 | — | 90° elbow |
| 63 | — | Tee |
| 63 | 50 | Reducer |
| 75 | — | 90° elbow |
| 75 | — | Tee |
| 75 | 63 | Reducer |
| 90 | — | 90° elbow |
| 90 | — | Tee |
| 90 | 75 | Reducer |
| 110 | — | 90° elbow |
| 110 | — | Tee |
| 110 | 90 | Reducer |
| 125 | — | 90° elbow |
| 125 | — | Tee |
| 125 | 110 | Reducer |
| 140 | — | 90° elbow |
| 140 | — | Tee |
| 140 | 125 | Reducer |
| 160 | — | 90° elbow |
| 160 | — | Tee |
| 160 | 140 | Reducer |
| 180 | — | 90° elbow |
| 180 | — | Tee |
| 180 | 160 | Reducer |
| 200 | — | 90° elbow |
| 200 | — | Tee |
| 200 | 180 | Reducer |
| 225 | — | 90° elbow |
| 225 | — | Tee |
| 225 | 200 | Reducer |
| 250 | — | 90° elbow |
| 250 | — | Tee |
| 250 | 225 | Reducer |
Electrofusion Elbow, Tee & Reducer — FAQ
How does it differ from a butt-fusion elbow?
An electrofusion elbow is fused with an electrofusion unit without moving the pipe; a butt-fusion elbow needs a butt-fusion machine.
Which electrofusion tee sizes are supplied?
Equal tees from 20 to 250 mm.
Are they suitable for gas?
Yes; they are listed to EN 1555-3 for gas networks.
Which machine is needed?
An electrofusion control unit that covers the fitting diameter.